Shielding Calculator
Transmission, half-value and tenth-value layer for a given photon energy and shield.
A screening tool; not a shielding design.
The calculation assumes narrow beam geometry and does NOT include the buildup factor. Under broad beam conditions real transmission is higher than shown, so more thickness is needed. This result does not replace a qualified health physicist’s calculation or an on-site measurement.
Result
%28,4
Transmission (I/I₀)
- Half-value layer (HVL)
- 5,5 mm
- Tenth-value layer (TVL)
- 18,27 mm
- Thickness for 1/10
- 18,27 mm
μ/ρ: NIST
Formula used
I / I₀ = e−(μ/ρ)·ρ·x
Mass attenuation coefficients μ/ρ are pulled from NIST. Intermediate energies use log–log interpolation; linear interpolation would introduce significant error because attenuation follows a near power law in energy.
NIST X-Ray Mass Attenuation Coefficients (SRD 126)Energy presets are only the gamma energies verified from IAEA SRS-49 Tables 6 and 7. For any other energy, type it directly.